<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Double-membrane reference electrodes &#8211; KM GROUP | Освещение и услуги для тяжелой промышленности</title>
	<atom:link href="https://kmgr.kz/en/product-tag/double-membrane-reference-electrodes/feed/" rel="self" type="application/rss+xml" />
	<link>https://kmgr.kz/en/</link>
	<description>Обеспечьте безопасность и эффективность вашего предприятия с нашими решениями по освещению и услугами для тяжелой промышленности от KM Group. От инновационных светодиодных систем до профессионального сервиса - мы помогаем вашему бизнесу процветать. Узнайте больше прямо сейчас!</description>
	<lastBuildDate>Sun, 08 Mar 2026 06:12:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>
	<item>
		<title>ECSM‑T2 stationary double‑membrane copper sulfate reference electrodes with solid electrolyte</title>
		<link>https://kmgr.kz/en/product/ecsm-t2-stationary-double-membrane-copper-sulfate-reference-electrodes-with-solid-electrolyte/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:49:41 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/ecsm-t2-stationary-double-membrane-copper-sulfate-reference-electrodes-with-solid-electrolyte/</guid>

					<description><![CDATA[The ECSM-T2 model must be purchased for measurements on underground metal structures. ECS are used to identify weak points in the anticorrosion coating. ECSM with solid electrolyte consists of two housings – outer and inner. The device can be used on any type of soil, including aggressive soils. Reference electrodes are installed above the structure [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The ECSM-T2 model must be purchased for measurements on underground metal structures. ECS are used to identify weak points in the anticorrosion coating.</p>
<p>ECSM with solid electrolyte consists of two housings – outer and inner. The device can be used on any type of soil, including aggressive soils. Reference electrodes are installed above the structure to be inspected. Installation is performed into the soil and below its freezing level.</p>
<p>The unit housing is made of durable material capable of withstanding moderate loads and damage. The measuring electrode is located in the lower part. The package includes a cable at least 5 meters long. ECSM-T2 can be ordered with a longer cable if required.</p>
<p>For convenient connection, the ECS housing has a terminal board. Each cable has an information label, which significantly simplifies connection, maintenance, and operation of the device. The price of ECSM-T2 double-membrane with solid electrolyte depends on additional components.</p>
<h3>Product Specifications</h3>
<p>The ECSM-T2 electrode group has the following characteristics:</p>
<ul>
<li aria-level="1">Resistance – does not exceed 10 kOhm;</li>
<li aria-level="1">Potential – from 100 to 130 mV;</li>
<li aria-level="1">Service life – minimum 30 years;</li>
<li aria-level="1">Weight – 4.2 kg without cables;</li>
<li aria-level="1">Cable length – minimum 2 meters.</li>
</ul>
<p>Delivery of ECSM-T2 and order details are coordinated with each customer. The product complies with GOST standards and can be used at minimum temperatures down to -5°C and maximum temperatures up to +45°C.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ECSM‑C2‑VE stationary double‑membrane copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/ecsm-c2-ve-stationary-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:41:59 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/ecsm-c2-ve-stationary-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[Copper sulfate ECS model ECSM-C2-VE must be purchased for performing measurements on underground metal structures. They are used to identify corrosion changes on objects such as pipelines and steel structures. The device allows timely detection of areas with developed corrosion. The measuring device consists of two housings – outer and inner. The outer housing is [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Copper sulfate ECS model ECSM-C2-VE must be purchased for performing measurements on underground metal structures. They are used to identify corrosion changes on objects such as pipelines and steel structures. The device allows timely detection of areas with developed corrosion.</p>
<p>The measuring device consists of two housings – outer and inner. The outer housing is made of durable ceramic, resistant to moderate damage and loads. The inner housing is filled with copper sulfate, in which a spiral-shaped electrode made of pure copper is immersed. The space between the housings is filled with a moisture-retaining bentonite-based material.</p>
<p>ECSM-C2-VE copper sulfate stationary double-membrane reference electrodes with auxiliary electrode can be ordered in two modifications. The ECSM-C2-VE model is equipped with an auxiliary electrode located in the lower part of the housing with its own terminal. The measuring device is installed in the ground above the inspected object and placed below the soil freezing level. The cables are connected via terminals to the control measurement point or can be led to a cable mat.</p>
<p>Reference electrodes are supplied with cables of standard length. At the customer’s request, this parameter can be increased. The final price of ECSM-C2-VE depends on the selected model modification and additional components. Each cable of the device is equipped with information labels and terminals, which facilitates connection, operation, and maintenance of the unit.</p>
<h3>Technical Specifications</h3>
<p>The device can be used at temperatures from -5°C to +45°C.</p>
<table width="669">
<tbody>
<tr>
<td>Parameters</td>
<td>Values</td>
</tr>
<tr>
<td>Weight, kg</td>
<td>4.2</td>
</tr>
<tr>
<td>Resistance, kOhm</td>
<td>10</td>
</tr>
<tr>
<td>Minimum cable length, m</td>
<td>2</td>
</tr>
<tr>
<td>Service life, years</td>
<td>30</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ECSM‑C2 stationary double‑membrane copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/ecsm-c2-stationary-double-membrane-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:38:20 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/ecsm-c2-stationary-double-membrane-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[Copper sulfate ECSM-C2 must be purchased for performing measurement and control operations on underground metal structures. Using ECS allows determining the level of protection of pipelines and other structures against corrosion. The double-membrane ECS model is intended for installation on the soil surface above the inspected structure. The device must be placed below the soil [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Copper sulfate ECSM-C2 must be purchased for performing measurement and control operations on underground metal structures. Using ECS allows determining the level of protection of pipelines and other structures against corrosion. The double-membrane ECS model is intended for installation on the soil surface above the inspected structure. The device must be placed below the soil freezing level.</p>
<p>Before ordering ECSM-C2, its design and operational features must be determined. The unit consists of two housings. Direct contact with the soil is created and maintained by the outer housing, which is made of durable ceramic. Inside it, there is a moisture-retaining bentonite filler. The inner housing is filled with copper sulfate. The measuring electrode is made of pure copper and immersed in the copper sulfate of the inner housing.</p>
<p>Depending on the modification, the ECS housing may include an auxiliary electrode (VE). It is installed in the lower part of the unit housing. Each cable is equipped with terminals for connecting the measuring device to KIP. The connecting cables are labeled with plates containing necessary information, which simplifies connection, operation, and maintenance of the copper sulfate ECS.</p>
<p>Reference electrodes come with cables of a specified length. When ordering, the required parameter can be selected, and ECS with longer cables can be purchased. The price of ECSM-C2 depends on additional components and agreed specifications. The model fully complies with GOST standards and has climatic category 5.</p>
<h3>Technical Specifications</h3>
<table width="659">
<tbody>
<tr>
<td>Parameters</td>
<td>Values</td>
</tr>
<tr>
<td>Service life, years</td>
<td>30</td>
</tr>
<tr>
<td>Weight, kg</td>
<td>4.2</td>
</tr>
<tr>
<td>Minimum cable length, m</td>
<td>2</td>
</tr>
<tr>
<td>Resistance, kOhm</td>
<td>10</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ESMS-M2 modernized double-membrane copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/esms-m2-modernized-double-membrane-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:20:28 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esms-m2-modernized-double-membrane-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[Reference electrodes should be purchased to perform measurement work on underground metal structures. Using this equipment, it is possible to assess the degree of corrosion protection of pipelines and other steel facilities. The modernized copper sulfate model can be equipped with an auxiliary electrode (VE). Double-membrane reference electrodes are used for installation in soil. The [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Reference electrodes should be purchased to perform measurement work on underground metal structures. Using this equipment, it is possible to assess the degree of corrosion protection of pipelines and other steel facilities. The modernized copper sulfate model can be equipped with an auxiliary electrode (VE).</p>
<p>Double-membrane reference electrodes are used for installation in soil. The unit should be positioned above the inspected structure. To perform measurements, the device must be buried to a level below the soil freezing depth. The conductors can be routed to a control measurement point or to a cover. The unit may be operated at ambient temperatures not lower than -5 and not higher than +45 degrees Celsius.</p>
<p>If required, reference electrodes can be ordered with auxiliary electrodes and an installation container. The device housing is made of durable material and filled with bentonite. The filler prevents diffusion between the soil and the electrolyte. Constant contact with the soil is ensured by the presence of capillary channels.</p>
<p>Each unit is supplied with cables. For more convenient operation and subsequent maintenance, each cable is equipped with connection terminals. All cables are marked with information tags. The order price depends on the selected cable length. The product is supplied with a minimum cable length of 3 meters, which can be increased upon request.</p>
<h3>Technical characteristics</h3>
<table width="578">
<tbody>
<tr>
<td>Parameters</td>
<td>Values</td>
</tr>
<tr>
<td>Service life, years</td>
<td>15</td>
</tr>
<tr>
<td>Weight, kg</td>
<td>0.6</td>
</tr>
<tr>
<td>Minimum cable length, m</td>
<td>3</td>
</tr>
<tr>
<td>Dimensions, cm</td>
<td>8&#215;17</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>10</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>Delivery and additional product parameters are agreed with the customer. The scope of supply includes:</p>
<ul>
<li aria-level="1">operation manual – 1 pc;</li>
<li aria-level="1">ESMS-M2 – 1 pc;</li>
<li aria-level="1">installation container (ordered separately) – 1 pc.</li>
</ul>
<p>Modernized reference electrodes comply with GOST requirements for climatic version and have placement category 5.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-02-(P-K)-T-VE stationary copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/mes-02-p-k-t-ve-stationary-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:07:11 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-02-p-k-t-ve-stationary-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[MES-02-(P-K)-T-VE stationary copper sulfate reference electrodes with an auxiliary electrode, designed to prevent or slow down corrosion processes, can be purchased from us. These devices also provide accurate measurements of total and polarization potentials on the metal surface. MES-02-(P-K)-T-VE are installed in soil below the freezing depth in accordance with the depth of the metal [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>MES-02-(P-K)-T-VE stationary copper sulfate reference electrodes with an auxiliary electrode, designed to prevent or slow down corrosion processes, can be purchased from us. These devices also provide accurate measurements of total and polarization potentials on the metal surface.</p>
<p>MES-02-(P-K)-T-VE are installed in soil below the freezing depth in accordance with the depth of the metal structure. The conductors are routed to a cover or to KIP and can be used as portable.</p>
<p>MES-02-(P-K)-T-VE stationary copper sulfate reference electrodes with an auxiliary electrode have a stable potential over a long period of time. The non-polarizable electrochemical system does not change its potential when a small current flows through it. This makes it possible to obtain accurate and reliable results in tests and measurements.</p>
<h3>Advantages</h3>
<p>The devices that can be ordered from us are ready for operation without the need for electrolyte preparation or filling by the operating organization.</p>
<p>The container housing the MES-02-(P-K)-T-VE stationary copper sulfate reference electrodes with an auxiliary electrode is made of vandal-resistant material.</p>
<p>Electrolytic contact with the soil is provided by capillary channels in the outer ceramic membrane with standardized porosity.</p>
<p>The customer determines the length of the connecting cables for MES-02-(P-K)-T-VE stationary copper sulfate reference electrodes with an auxiliary electrode.</p>
<h3>Characteristics</h3>
<p>A special bentonite chamber prevents mixing of the electrode electrolyte and the soil electrolyte.</p>
<p>Spreading resistance is not more than 5 kΩ.</p>
<p>The average potential relative to a laboratory silver/silver chloride reference electrode is 100±20 mV.</p>
<p>The cable outlet does not have a fixed length; it is selected according to customer requirements, but not less than 2 m.</p>
<p>The manufacturer guarantees operation of the reference electrodes for up to 30 years.</p>
<p>Weight, excluding cable outlets, from 2.5 kg.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-02-(P-K)-G-VE-M stationary modernized copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/mes-02-p-k-g-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:02:16 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-02-p-k-g-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[MES-02-(P-K)-G-VE-M are modernized stationary double-membrane copper sulfate reference electrodes with gel filling and an auxiliary electrode, equipped with polymer and ceramic membranes.
]]></description>
										<content:encoded><![CDATA[<p>Stationary reference electrodes are recommended for purchase when measurements on pipelines and underground metal structures are required. They are used to measure the potential of structures and to monitor the degree of corrosion protection.</p>
<p>Modernized copper sulfate reference electrodes of the MES-02-(P-K)-G-VE-M model are stationary. They are installed directly above the metal structure. The reference electrode is buried in the soil to a level below the soil freezing depth. Measurements performed using the device comply with GOST requirements.</p>
<p>The outer housing of the reference electrode is made of porous ceramic, which increases its service life. The material ensures stable operation of the unit in different soil types. The inner housing is surrounded by bentonite filler, which provides moisture retention. A spiral electrode made of pure copper is immersed in copper sulfate. This model can be ordered with measuring cables with a length of at least 2 meters.</p>
<p>The use of the auxiliary electrode allows measurements to be performed using the polarization current interruption method. The cables are equipped with terminals for convenient connection. Marking information tags on the cable outlets allow easier maintenance and operation of the unit.</p>
<p>Modernized copper sulfate reference electrodes consist of:</p>
<ul>
<li aria-level="1">outer and inner housings;</li>
<li aria-level="1">bentonite filler;</li>
<li aria-level="1">measuring cable;</li>
<li aria-level="1">heat-shrink sleeve;</li>
<li aria-level="1">cable lug.</li>
</ul>
<p>Depending on the cable length selected by the customer, the final order price may vary.</p>
<h3>Product characteristics</h3>
<table width="584">
<tbody>
<tr>
<td>Parameters</td>
<td>Value</td>
</tr>
<tr>
<td>Cable length, m</td>
<td>from 2</td>
</tr>
<tr>
<td>Weight without cables, kg</td>
<td>1.5</td>
</tr>
<tr>
<td>Service life, years</td>
<td>10</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>5</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
<p>Reference electrodes can be used in different soil types (arid, saline, etc.). The measuring cable in the device is load-bearing and is used for installation of the electrode.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-02-(P-K)-G-VE stationary copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/mes-02-p-k-g-ve-stationary-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:58:33 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-02-p-k-g-ve-stationary-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[MES-02-(P-K)-G-VE are stationary double-membrane copper sulfate reference electrodes with gel filling and an auxiliary electrode, equipped with polymer and ceramic membranes.]]></description>
										<content:encoded><![CDATA[<p>Copper sulfate reference electrodes can be purchased to perform measurements on various types of pipelines and other structures. Stationary reference electrodes are used to measure the degree of protection of metal structures against corrosion.</p>
<p>The MES-02-(P-K)-G-VE model has its own features – it is a double-housing device. The outer ceramic housing is intended to create and maintain electrolytic contact during measurements. The porous ceramic is sufficiently strong and capable of withstanding moderate mechanical воздействия. Inside it there is a measuring module. This is the second housing filled with copper sulfate. The reference electrode is located in it. The space between the housings is filled with a moisture-retaining substance.</p>
<p>To measure the polarization potential, the device is equipped with an auxiliary electrode. The VE is located in the lower part of the housing and is connected to terminals. Marked cables are routed from the main and auxiliary electrodes. The information tags are intended for more convenient operation and maintenance of the reference electrodes. Stationary copper sulfate reference electrodes with an auxiliary electrode (VE) can be ordered for performing measurements in arid regions.</p>
<p>The double-housing reference electrode includes in its design:</p>
<ul>
<li aria-level="1">measuring module;</li>
<li aria-level="1">outer and inner housings;</li>
<li aria-level="1">moisture-retaining filling;</li>
<li aria-level="1">auxiliary electrode and cable;</li>
<li aria-level="1">heat-shrink sleeve.</li>
</ul>
<p>The device can be operated at temperatures from 0 to +55 degrees Celsius.</p>
<h3>Product characteristics</h3>
<p>The copper sulfate reference electrode is supplied with cable outlets with a length of at least 2 meters. When placing an order, the required cable length can be specified. The final price of the product depends on this parameter.</p>
<table width="554">
<tbody>
<tr>
<td>Parameters</td>
<td>Value</td>
</tr>
<tr>
<td>Weight, kg</td>
<td>4.2</td>
</tr>
<tr>
<td>Minimum cable length, m</td>
<td>2</td>
</tr>
<tr>
<td>Service life, years</td>
<td>30</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>5</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ESMS.KMG-2-VE double-membrane copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/esms-ptm-2-ve-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:37:18 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esms-ptm-2-ve-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[Copper sulfate reference electrodes should be purchased to perform measurements on metal structures. This device makes it possible to determine the degree of corrosion protection of pipelines and other structures located underground. Double-membrane copper sulfate reference electrodes have an additional electrode in their design. The device is installed directly above the inspected object and buried [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Copper sulfate reference electrodes should be purchased to perform measurements on metal structures. This device makes it possible to determine the degree of corrosion protection of pipelines and other structures located underground.</p>
<p>Double-membrane copper sulfate reference electrodes have an additional electrode in their design. The device is installed directly above the inspected object and buried below the soil freezing depth. The advantages of the copper sulfate reference electrode include:</p>
<ul>
<li aria-level="1">complete readiness for use;</li>
<li aria-level="1">bentonite chamber;</li>
<li aria-level="1">sealed housing;</li>
<li aria-level="1">the ability to independently select the cable length.</li>
</ul>
<p>The unit is fully ready for use and does not require additional preparation. The housing is made of a durable material capable of withstanding moderate mechanical damage. The customer can independently determine the required cable length. The final price of the device depends on this parameter.</p>
<p>The manufacturer offers reference electrodes in several modifications. The ESMS.KMG-2-VE model is distinguished by the presence of VE (auxiliary electrode). Inside the housing there is a copper electrode. The housing is filled with copper sulfate. To maintain constant contact, an ion-exchange membrane is provided in the lower part of the structure.</p>
<p>The standard cable length is set at 3 meters and cannot be shorter. The customer can order reference electrodes only with a greater cable length. Each cable has an information tag. This significantly simplifies maintenance and servicing of the unit. Each cable is equipped with terminals for connection to KIP.</p>
<h3>Technical parameters</h3>
<p>Double-membrane reference electrodes with VE can be used at a minimum temperature of -5 °C and a maximum of +45 °C.</p>
<table width="603">
<tbody>
<tr>
<td>Parameters</td>
<td>Value</td>
</tr>
<tr>
<td>Dimensions, cm</td>
<td>8&#215;17</td>
</tr>
<tr>
<td>Weight, kg</td>
<td>2</td>
</tr>
<tr>
<td>Service life, years</td>
<td>10</td>
</tr>
<tr>
<td>Cable length</td>
<td>3</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>15</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>Delivery of the order is possible in individual or group packaging. The scope of supply includes:</p>
<ul>
<li aria-level="1">reference electrode user manual – 1 pc;</li>
<li aria-level="1">installation container – 1 pc;</li>
<li aria-level="1">double-membrane copper sulfate reference electrode – 1 pc.</li>
</ul>
<p>Special notes when ordering include the installation container. It must be ordered separately. The product complies with the requirements of GOST.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ESMS-M2-VE modernized double-membrane copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/esms-m2-ve-modernized-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:28:21 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esms-m2-ve-modernized-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[Measurement of the condition of metal structures in soil is performed using reference electrodes, which can be purchased for measurements at various sites. Several versions of copper sulfate reference electrodes are available, both single-membrane and double-membrane. Description The ESMS-M2-VE model is an installation for monitoring the condition of underground metal objects. It should be ordered [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Measurement of the condition of metal structures in soil is performed using reference electrodes, which can be purchased for measurements at various sites. Several versions of copper sulfate reference electrodes are available, both single-membrane and double-membrane.</p>
<h3>Description</h3>
<p>The ESMS-M2-VE model is an installation for monitoring the condition of underground metal objects. It should be ordered when accurate control of corrosion changes of pipelines and other steel structures is required. The modernized copper sulfate reference electrodes are equipped with an auxiliary electrode and have two membranes.</p>
<p>The operating principle consists in installing the device directly in the soil. The depth must correspond to the laying level of the object under inspection and must not be above the soil freezing depth. The conductors of the unit can be used as portable, and routed to a cover or to KIP.</p>
<p>Double-membrane modernized copper sulfate reference electrodes with auxiliary electrodes have the following advantages:</p>
<ul>
<li aria-level="1">bentonite chamber;</li>
<li aria-level="1">fully sealed housing;</li>
<li aria-level="1">durable construction material;</li>
<li aria-level="1">the unit is ready for use;</li>
<li aria-level="1">cable length can be specified by the customer.</li>
</ul>
<p>When working with the reference electrodes, no preparation or electrolyte filling is required. The device housing is capable of withstanding impacts and other moderate mechanical damage. When purchasing reference electrodes, the customer can independently choose the required cable length. The final order price depends on this parameter.</p>
<h3>Technical features</h3>
<p>Several modifications of reference electrodes are available. In addition to the basic version, the manufacturer offers the ESMS-VE-M model. This device is supplemented with an auxiliary electrode. The housing is filled with copper sulfate, with a pure copper electrode inside. Contact with the soil surface is maintained by an ion-exchange membrane located in the lower part. The auxiliary electrode is located on the side of the reference electrode housing.</p>
<p>Each cable has tags with information and lugs for connection to KIP. This makes installation, operation, and maintenance of the unit convenient and clear.</p>
<p>Technical characteristics:</p>
<table width="690">
<tbody>
<tr>
<td width="287">Parameters</td>
<td width="213">Value</td>
</tr>
<tr>
<td width="287">Weight, kg</td>
<td width="213">2</td>
</tr>
<tr>
<td width="287">Cable length, m</td>
<td width="213">1</td>
</tr>
<tr>
<td width="287">Potential, mV</td>
<td width="213">100</td>
</tr>
<tr>
<td width="287">Resistance, kΩ</td>
<td width="213">15</td>
</tr>
<tr>
<td width="287">Dimensions, cm</td>
<td width="213">8&#215;17</td>
</tr>
<tr>
<td width="287">Service life, years</td>
<td width="213">10</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The device can be used at temperatures from -5 to +45 degrees Celsius. The scope of supply includes:</p>
<ul>
<li aria-level="1">User manual – 1 pc;</li>
<li aria-level="1">Installation container (ordered separately) – 1 pc;</li>
<li aria-level="1">Modernized copper sulfate reference electrode ESMS-M2-VE – 1 pc.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-02-(P-K)-T-VE-M stationary modernized copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/mes-02-p-k-t-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:11:57 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-02-p-k-t-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[In cathodic protection systems against corrosion, modernized double-membrane copper sulfate reference electrodes based on a combined gel and solid electrolyte with an auxiliary electrode of type KMG-MES-02-(P-K)-(G-T)-VE-M manufactured by KM GROUP are used, which serve to measure polarization and total potentials of protected underground metal structures – they can be purchased on our website. According [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>In cathodic protection systems against corrosion, modernized double-membrane copper sulfate reference electrodes based on a combined gel and solid electrolyte with an auxiliary electrode of type KMG-MES-02-(P-K)-(G-T)-VE-M manufactured by KM GROUP are used, which serve to measure polarization and total potentials of protected underground metal structures – they can be purchased on our website. According to GOST 9.602-2016, all underground metal structures must be provided with a protective polarized potential, the values of which can be measured using stationary long-life copper sulfate reference electrodes manufactured by KM GROUP. The product consists of the following elements:</p>
<ul>
<li aria-level="1">copper electrode;</li>
<li aria-level="1">gel-like saturated solution of copper(II) sulfate pentahydrate according to GOST 19347;</li>
<li aria-level="1">ion-exchange polymer membrane;</li>
<li aria-level="1">inner housing;</li>
<li aria-level="1">contact unit (ion-exchange ceramic membrane);</li>
<li aria-level="1">contact electrolytic mass or its gel-like solution;</li>
<li aria-level="1">housing;</li>
<li aria-level="1">auxiliary electrode;</li>
<li aria-level="1">cable outlet with cable.</li>
</ul>
<h3>Technical description</h3>
<p>To ensure a stable electrolytic junction between the reference electrode and the soil electrolyte at the level of the lowest resistance required when performing specific measurements of protective potential values, an ion-exchange ceramic membrane with standardized porosity is used in the long-life reference electrode. The internal cavity of the outer housing is filled with a contact electrolytic mass based on bentonite clay. The inner housing of KMG-MES-02-(P-K)-(G-T)-VE-M is filled with a gel-like saturated copper solution in which the electrode is located in the form of a spiral made of pure refined copper.</p>
<p>Under certain soil conditions, such as increased soil resistivity, the so-called “arid soils”, the KMG-MES-02-(P-K)-(G-T)-VE-M reference electrode gains higher stability and durability due to the fact that the outer housing is filled with a special moisture-retaining electrolytic mass based on bentonite.</p>
<p>To ensure convenient installation and subsequent operation of the products, the cables of the reference electrode and the auxiliary electrode are equipped with cable lugs for connection to KIP.</p>