<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Modernized reference electrodes &#8211; KM GROUP | Освещение и услуги для тяжелой промышленности</title>
	<atom:link href="https://kmgr.kz/en/product-tag/modernized-reference-electrodes/feed/" rel="self" type="application/rss+xml" />
	<link>https://kmgr.kz/en/</link>
	<description>Обеспечьте безопасность и эффективность вашего предприятия с нашими решениями по освещению и услугами для тяжелой промышленности от KM Group. От инновационных светодиодных систем до профессионального сервиса - мы помогаем вашему бизнесу процветать. Узнайте больше прямо сейчас!</description>
	<lastBuildDate>Sun, 08 Mar 2026 06:12:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>
	<item>
		<title>ESMS-M2 modernized double-membrane copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/esms-m2-modernized-double-membrane-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:20:28 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esms-m2-modernized-double-membrane-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[Reference electrodes should be purchased to perform measurement work on underground metal structures. Using this equipment, it is possible to assess the degree of corrosion protection of pipelines and other steel facilities. The modernized copper sulfate model can be equipped with an auxiliary electrode (VE). Double-membrane reference electrodes are used for installation in soil. The [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Reference electrodes should be purchased to perform measurement work on underground metal structures. Using this equipment, it is possible to assess the degree of corrosion protection of pipelines and other steel facilities. The modernized copper sulfate model can be equipped with an auxiliary electrode (VE).</p>
<p>Double-membrane reference electrodes are used for installation in soil. The unit should be positioned above the inspected structure. To perform measurements, the device must be buried to a level below the soil freezing depth. The conductors can be routed to a control measurement point or to a cover. The unit may be operated at ambient temperatures not lower than -5 and not higher than +45 degrees Celsius.</p>
<p>If required, reference electrodes can be ordered with auxiliary electrodes and an installation container. The device housing is made of durable material and filled with bentonite. The filler prevents diffusion between the soil and the electrolyte. Constant contact with the soil is ensured by the presence of capillary channels.</p>
<p>Each unit is supplied with cables. For more convenient operation and subsequent maintenance, each cable is equipped with connection terminals. All cables are marked with information tags. The order price depends on the selected cable length. The product is supplied with a minimum cable length of 3 meters, which can be increased upon request.</p>
<h3>Technical characteristics</h3>
<table width="578">
<tbody>
<tr>
<td>Parameters</td>
<td>Values</td>
</tr>
<tr>
<td>Service life, years</td>
<td>15</td>
</tr>
<tr>
<td>Weight, kg</td>
<td>0.6</td>
</tr>
<tr>
<td>Minimum cable length, m</td>
<td>3</td>
</tr>
<tr>
<td>Dimensions, cm</td>
<td>8&#215;17</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>10</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>Delivery and additional product parameters are agreed with the customer. The scope of supply includes:</p>
<ul>
<li aria-level="1">operation manual – 1 pc;</li>
<li aria-level="1">ESMS-M2 – 1 pc;</li>
<li aria-level="1">installation container (ordered separately) – 1 pc.</li>
</ul>
<p>Modernized reference electrodes comply with GOST requirements for climatic version and have placement category 5.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ESMS-M modernized copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/esms-m-modernized-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:16:49 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esms-m-modernized-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[To measure the cathodic protection of metal structures, modernized copper sulfate reference electrodes are required. They are used on underground structures of various purposes. The device allows measurements to be carried out on pipelines and other steel structures. The equipment is installed above the structure and embedded into the soil. A mandatory condition is installation [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>To measure the cathodic protection of metal structures, modernized copper sulfate reference electrodes are required. They are used on underground structures of various purposes. The device allows measurements to be carried out on pipelines and other steel structures.</p>
<p>The equipment is installed above the structure and embedded into the soil. A mandatory condition is installation of the reference electrode below the soil freezing depth. The conductors are routed to a control measurement point or to a cover. Copper sulfate reference electrodes can be used as portable.</p>
<p>The unit can be ordered in several modifications. Among the available models are devices with an auxiliary electrode (VE). Operation of the reference electrodes is permitted at temperatures from -5 to +45 degrees Celsius. The product complies with GOST standards.</p>
<p>The housing of the modernized reference electrodes is made of durable material, is sealed, and is capable of withstanding moderate damage. Capillary-type channels are provided to ensure contact with the soil. Bentonite filling is located between the outer and inner housings.</p>
<p>The model may have different cable lengths. This parameter is agreed separately with the customer. The final price depends on the selected length of the connecting cables. Each cable is equipped with a terminal for connection and has an information tag. This significantly simplifies operation and maintenance of the device.</p>
<h3>Technical characteristics</h3>
<table width="672">
<tbody>
<tr>
<td>Parameters</td>
<td>Values</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>10</td>
</tr>
<tr>
<td>Minimum cable length, m</td>
<td>3</td>
</tr>
<tr>
<td>Weight, g</td>
<td>600</td>
</tr>
<tr>
<td>Dimensions, cm</td>
<td>8&#215;17</td>
</tr>
<tr>
<td>Service life, years</td>
<td>15</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>By agreement with the customer, delivery is carried out with or without an installation container. Each equipment set includes an operation manual. Additional components can be added at the ordering stage.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-02-(P-K)-G-VE-M stationary modernized copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/mes-02-p-k-g-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 14:02:16 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-02-p-k-g-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[MES-02-(P-K)-G-VE-M are modernized stationary double-membrane copper sulfate reference electrodes with gel filling and an auxiliary electrode, equipped with polymer and ceramic membranes.
]]></description>
										<content:encoded><![CDATA[<p>Stationary reference electrodes are recommended for purchase when measurements on pipelines and underground metal structures are required. They are used to measure the potential of structures and to monitor the degree of corrosion protection.</p>
<p>Modernized copper sulfate reference electrodes of the MES-02-(P-K)-G-VE-M model are stationary. They are installed directly above the metal structure. The reference electrode is buried in the soil to a level below the soil freezing depth. Measurements performed using the device comply with GOST requirements.</p>
<p>The outer housing of the reference electrode is made of porous ceramic, which increases its service life. The material ensures stable operation of the unit in different soil types. The inner housing is surrounded by bentonite filler, which provides moisture retention. A spiral electrode made of pure copper is immersed in copper sulfate. This model can be ordered with measuring cables with a length of at least 2 meters.</p>
<p>The use of the auxiliary electrode allows measurements to be performed using the polarization current interruption method. The cables are equipped with terminals for convenient connection. Marking information tags on the cable outlets allow easier maintenance and operation of the unit.</p>
<p>Modernized copper sulfate reference electrodes consist of:</p>
<ul>
<li aria-level="1">outer and inner housings;</li>
<li aria-level="1">bentonite filler;</li>
<li aria-level="1">measuring cable;</li>
<li aria-level="1">heat-shrink sleeve;</li>
<li aria-level="1">cable lug.</li>
</ul>
<p>Depending on the cable length selected by the customer, the final order price may vary.</p>
<h3>Product characteristics</h3>
<table width="584">
<tbody>
<tr>
<td>Parameters</td>
<td>Value</td>
</tr>
<tr>
<td>Cable length, m</td>
<td>from 2</td>
</tr>
<tr>
<td>Weight without cables, kg</td>
<td>1.5</td>
</tr>
<tr>
<td>Service life, years</td>
<td>10</td>
</tr>
<tr>
<td>Resistance, kΩ</td>
<td>5</td>
</tr>
<tr>
<td>Potential, mV</td>
<td>100</td>
</tr>
</tbody>
</table>
<p>Reference electrodes can be used in different soil types (arid, saline, etc.). The measuring cable in the device is load-bearing and is used for installation of the electrode.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-01-(K)-G-VE-M stationary modernized copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/mes-01-k-g-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:49:58 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-01-k-g-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[MES-01-(K)-G-VE-M are modernized stationary single-membrane copper sulfate reference electrodes with gel filling and an auxiliary electrode, equipped with a ceramic membrane.
]]></description>
										<content:encoded><![CDATA[<p>Reference electrodes are special elements that can be purchased on our website with delivery. They are used to provide cathodic protection against corrosion and are applied for measuring potentials on operating underground steel pipelines and structures.</p>
<p>They are installed in the soil, with the depth determined by the laying level of the metal structure. The conductor is routed to a cover or to KIP; they can also be used as portable. The products are considered non-polarizable and have a long service life.</p>
<h3>Product characteristics</h3>
<p>The manufacturer ensures that stationary reference electrodes MES-01-(K)-G-VE-M are fully ready for operation. The operating organization does not need to prepare or fill the electrolyte in the future. The product has the following characteristics:</p>
<ul>
<li aria-level="1">Service life – from 30 years;</li>
<li aria-level="1">Spreading resistance – up to 5 kΩ;</li>
<li aria-level="1">Potential relative to a laboratory silver/silver chloride reference electrode – 100 mV with an accuracy of ±20;</li>
<li aria-level="1">Cable outlet length – not less than 200 cm;</li>
<li aria-level="1">Weight – not more than 2500 g.</li>
</ul>
<p>To ensure the housing is sealed, materials with high impact resistance are used. The ceramic membrane with standardized porosity contains capillary channels that provide electrolytic contact with the soil. The length of the connecting cables is determined according to customer requirements. Mutual diffusion of the electrode electrolyte and the soil electrolyte is prevented by the presence of a special bentonite chamber. MES-01-(K)-G-VE-M can be ordered on our website with delivery.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ESMS-M2-VE modernized double-membrane copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/esms-m2-ve-modernized-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:28:21 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esms-m2-ve-modernized-double-membrane-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[Measurement of the condition of metal structures in soil is performed using reference electrodes, which can be purchased for measurements at various sites. Several versions of copper sulfate reference electrodes are available, both single-membrane and double-membrane. Description The ESMS-M2-VE model is an installation for monitoring the condition of underground metal objects. It should be ordered [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Measurement of the condition of metal structures in soil is performed using reference electrodes, which can be purchased for measurements at various sites. Several versions of copper sulfate reference electrodes are available, both single-membrane and double-membrane.</p>
<h3>Description</h3>
<p>The ESMS-M2-VE model is an installation for monitoring the condition of underground metal objects. It should be ordered when accurate control of corrosion changes of pipelines and other steel structures is required. The modernized copper sulfate reference electrodes are equipped with an auxiliary electrode and have two membranes.</p>
<p>The operating principle consists in installing the device directly in the soil. The depth must correspond to the laying level of the object under inspection and must not be above the soil freezing depth. The conductors of the unit can be used as portable, and routed to a cover or to KIP.</p>
<p>Double-membrane modernized copper sulfate reference electrodes with auxiliary electrodes have the following advantages:</p>
<ul>
<li aria-level="1">bentonite chamber;</li>
<li aria-level="1">fully sealed housing;</li>
<li aria-level="1">durable construction material;</li>
<li aria-level="1">the unit is ready for use;</li>
<li aria-level="1">cable length can be specified by the customer.</li>
</ul>
<p>When working with the reference electrodes, no preparation or electrolyte filling is required. The device housing is capable of withstanding impacts and other moderate mechanical damage. When purchasing reference electrodes, the customer can independently choose the required cable length. The final order price depends on this parameter.</p>
<h3>Technical features</h3>
<p>Several modifications of reference electrodes are available. In addition to the basic version, the manufacturer offers the ESMS-VE-M model. This device is supplemented with an auxiliary electrode. The housing is filled with copper sulfate, with a pure copper electrode inside. Contact with the soil surface is maintained by an ion-exchange membrane located in the lower part. The auxiliary electrode is located on the side of the reference electrode housing.</p>
<p>Each cable has tags with information and lugs for connection to KIP. This makes installation, operation, and maintenance of the unit convenient and clear.</p>
<p>Technical characteristics:</p>
<table width="690">
<tbody>
<tr>
<td width="287">Parameters</td>
<td width="213">Value</td>
</tr>
<tr>
<td width="287">Weight, kg</td>
<td width="213">2</td>
</tr>
<tr>
<td width="287">Cable length, m</td>
<td width="213">1</td>
</tr>
<tr>
<td width="287">Potential, mV</td>
<td width="213">100</td>
</tr>
<tr>
<td width="287">Resistance, kΩ</td>
<td width="213">15</td>
</tr>
<tr>
<td width="287">Dimensions, cm</td>
<td width="213">8&#215;17</td>
</tr>
<tr>
<td width="287">Service life, years</td>
<td width="213">10</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The device can be used at temperatures from -5 to +45 degrees Celsius. The scope of supply includes:</p>
<ul>
<li aria-level="1">User manual – 1 pc;</li>
<li aria-level="1">Installation container (ordered separately) – 1 pc;</li>
<li aria-level="1">Modernized copper sulfate reference electrode ESMS-M2-VE – 1 pc.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ESMC-M-VE modernized copper sulfate reference electrodes with auxiliary electrode</title>
		<link>https://kmgr.kz/en/product/esmc-m-ve-modernized-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:24:40 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/esmc-m-ve-modernized-copper-sulfate-reference-electrodes-with-auxiliary-electrode/</guid>

					<description><![CDATA[The main function of ESMS reference devices is to monitor the condition of underground metal structures; such devices can be supplied in several modifications. ES allow work to be performed under various conditions, including over large sections. The device is intended for control measurements on underground metal structures, including pipelines and other constructions. Modernized copper [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The main function of ESMS reference devices is to monitor the condition of underground metal structures; such devices can be supplied in several modifications. ES allow work to be performed under various conditions, including over large sections.</p>
<p>The device is intended for control measurements on underground metal structures, including pipelines and other constructions. Modernized copper sulfate reference electrodes with an auxiliary electrode make it possible to determine the degree of protection of the facility against corrosion.</p>
<p>The method of operation of the electrodes consists in installing the device below the soil freezing depth. The measurements are based on oxidation and reduction reactions. The design provides for bringing the conductors directly to a cover or to KIP. The modernized reference electrodes are non-polarizable and have a long service life.</p>
<p>Advantages:</p>
<ol>
<li>The model can be ordered with a specified length of connecting cables.</li>
<li>The device is fully ready for use. There is no need to fill electrolyte or perform other preparatory operations.</li>
<li>The outer housing is made of durable and sealed material. It withstands impacts and mechanical damage.</li>
<li>The modernized copper sulfate reference electrodes with an auxiliary electrode have a bentonite chamber.</li>
<li>The porosity of the capillary channels of the outer ceramic membrane is standardized. This ensures good electrolytic contact with the soil at the measurement point.</li>
</ol>
<h3>Technical features</h3>
<p>Two modification types of reference electrodes are available. Their difference lies in the auxiliary electrode, which is present in the ESMC-M-VE model. The ESMC device does not have such an electrode. Inside the housing of the additional element there is copper sulfate. A spiral-shaped copper electrode made of refined copper is located in it.</p>
<p>During operation of the device, the preservation of the electrolyte volume in the housing is ensured by an ion membrane. With its help, electrolytic contact of the mass with the electrode is constantly maintained. The material of the contact mass is bentonite clay. Its purpose in the device is to ensure contact with the soil under conditions of low moisture. A porous diaphragm located in the lower part of the device housing serves to provide contact between the soil and the mass.</p>
<p>The auxiliary electrode makes it possible to measure the polarization potential in a pipeline. It is present in the ESMC-M-VE modification model. The equipment is supplied with cable outlets already installed, which have marking tags. This significantly simplifies maintenance of the modernized copper sulfate reference electrodes with an auxiliary electrode. The minimum length of the outlet cables is 5 meters and can be increased at the request of the customer.</p>
<p>One of the important advantages of these ES devices is the stable values of their own potential. Due to this, the measurements are максимально accurate. The minimum operating temperature is -5 °C, the maximum is +45 °C.</p>
<p>Copper sulfate reference electrodes have a special container for installation. Its housing consists of:</p>
<ul>
<li>PVC pipe;</li>
<li>sealed cover;</li>
<li>sealed cover;</li>
<li>sealing ring;</li>
<li>cable outlets.</li>
</ul>
<p>The PVC container is intended for installation and removal of the device from the soil surface. The material is sufficiently strong and does not deform during operation. A special terminal plate is located on the housing, to which the electrode leads are connected. They are connected using terminals.</p>
<p>The cable outlet points are hermetically sealed. The standard length of the installation container is 220 cm. The customer can change this parameter when placing an order. The price will depend on the selected length. The diameter has a constant value of 16 cm.</p>
<p>To establish contact of the electrode with the soil surface, the container has perforations at the bottom of the device. The upper part of the installation container is closed and completely sealed.</p>
<p>Technical parameters:</p>
<table width="761">
<tbody>
<tr>
<td width="287">Characteristics</td>
<td width="213">Value</td>
</tr>
<tr>
<td width="287">Dimensions, cm</td>
<td width="213">30, 11</td>
</tr>
<tr>
<td width="287">– ESMC-VE</td>
<td width="213">30, 13</td>
</tr>
<tr>
<td width="287">– ESMC</td>
<td width="213"></td>
</tr>
<tr>
<td width="287">Cable outlet, m</td>
<td width="213">from 5</td>
</tr>
<tr>
<td width="287">Weight with 5 m cable, kg</td>
<td width="213">from 4 to 4.8</td>
</tr>
<tr>
<td width="287">Service life, years</td>
<td width="213">from 5</td>
</tr>
<tr>
<td width="287">Spreading resistance, kΩ</td>
<td width="213">up to 15</td>
</tr>
<tr>
<td width="287">Potential, mV</td>
<td width="213">100</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-02-(P-K)-T-VE-M stationary modernized copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/mes-02-p-k-t-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 13:11:57 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-02-p-k-t-ve-m-stationary-modernized-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[In cathodic protection systems against corrosion, modernized double-membrane copper sulfate reference electrodes based on a combined gel and solid electrolyte with an auxiliary electrode of type KMG-MES-02-(P-K)-(G-T)-VE-M manufactured by KM GROUP are used, which serve to measure polarization and total potentials of protected underground metal structures – they can be purchased on our website. According [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>In cathodic protection systems against corrosion, modernized double-membrane copper sulfate reference electrodes based on a combined gel and solid electrolyte with an auxiliary electrode of type KMG-MES-02-(P-K)-(G-T)-VE-M manufactured by KM GROUP are used, which serve to measure polarization and total potentials of protected underground metal structures – they can be purchased on our website. According to GOST 9.602-2016, all underground metal structures must be provided with a protective polarized potential, the values of which can be measured using stationary long-life copper sulfate reference electrodes manufactured by KM GROUP. The product consists of the following elements:</p>
<ul>
<li aria-level="1">copper electrode;</li>
<li aria-level="1">gel-like saturated solution of copper(II) sulfate pentahydrate according to GOST 19347;</li>
<li aria-level="1">ion-exchange polymer membrane;</li>
<li aria-level="1">inner housing;</li>
<li aria-level="1">contact unit (ion-exchange ceramic membrane);</li>
<li aria-level="1">contact electrolytic mass or its gel-like solution;</li>
<li aria-level="1">housing;</li>
<li aria-level="1">auxiliary electrode;</li>
<li aria-level="1">cable outlet with cable.</li>
</ul>
<h3>Technical description</h3>
<p>To ensure a stable electrolytic junction between the reference electrode and the soil electrolyte at the level of the lowest resistance required when performing specific measurements of protective potential values, an ion-exchange ceramic membrane with standardized porosity is used in the long-life reference electrode. The internal cavity of the outer housing is filled with a contact electrolytic mass based on bentonite clay. The inner housing of KMG-MES-02-(P-K)-(G-T)-VE-M is filled with a gel-like saturated copper solution in which the electrode is located in the form of a spiral made of pure refined copper.</p>
<p>Under certain soil conditions, such as increased soil resistivity, the so-called “arid soils”, the KMG-MES-02-(P-K)-(G-T)-VE-M reference electrode gains higher stability and durability due to the fact that the outer housing is filled with a special moisture-retaining electrolytic mass based on bentonite.</p>
<p>To ensure convenient installation and subsequent operation of the products, the cables of the reference electrode and the auxiliary electrode are equipped with cable lugs for connection to KIP.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MES-01-(K)-T-VE-M modernized single-membrane copper sulfate reference electrodes</title>
		<link>https://kmgr.kz/en/product/mes-01-k-t-ve-m-modernized-single-membrane-copper-sulfate-reference-electrodes/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 02 Nov 2025 12:57:03 +0000</pubDate>
				<guid isPermaLink="false">https://kmgr.kz/product/mes-01-k-t-ve-m-modernized-single-membrane-copper-sulfate-reference-electrodes/</guid>

					<description><![CDATA[We offer copper sulfate single-membrane reference electrodes based on a solid electrolyte with an auxiliary electrode, modernized type KMG-MES-01-(K)-T-VE-M, which are used in cathodic protection systems for underground steel pipelines and structures, as well as in water, in aqueous electrolyte solutions – produced water from watered crude oil, oil, diesel fuel, gas condensate, fuel oil, [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>We offer copper sulfate single-membrane reference electrodes based on a solid electrolyte with an auxiliary electrode, modernized type KMG-MES-01-(K)-T-VE-M, which are used in cathodic protection systems for underground steel pipelines and structures, as well as in water, in aqueous electrolyte solutions – produced water from watered crude oil, oil, diesel fuel, gas condensate, fuel oil, and vacuum gas oil. KMG-MES-01-(K)-T-VE-M is a stationary device with a long service life for measuring polarization and total potentials.</p>
<p>KMG-MES-01-(K)-T-VE-M are installed directly in the soil at the level of the lower generatrix of the protected structure, at a distance of no more than 0.1 m. The installation depth is selected according to the location of the underground metal structure. It is important that KMG-MES-01-(K)-T-VE-M is located below the soil freezing depth. The cables are equipped with terminals for connection to the terminal panel in KIP or in a cover.</p>
<p>Equipped with an auxiliary electrode made of carbon steel with a contact area of at least 625 mm2. They can also be used as portable units.</p>
<h3>Advantages</h3>
<p>The product is supplied fully factory-ready for operation, i.e., it does not require prolonged pre-soaking before installation in the soil to activate the electrolytic junction.</p>
<p>The housing of KMG-MES-01-(K)-T-VE-M is made of impact-resistant frost-resistant material and is completely sealed.</p>
<p>Electrolytic contact with the soil is formed through capillary channels of the external ceramic membrane with standardized porosity.</p>
<p>The length of the cables of the reference electrode and the auxiliary electrode is not fixed and is specified by the customer.</p>
<p>The presence of an additional chamber (double-membrane reference electrodes) eliminates mutual diffusion of the electrode electrolyte and soil electrolyte by using a solid-state electrolyte based on bentonite.</p>
<p>You can order reference electrodes from us with delivery at an attractive price.</p>