{"id":13074,"date":"2025-11-02T11:34:49","date_gmt":"2025-11-02T11:34:49","guid":{"rendered":"https:\/\/kmgr.kz\/product\/kip-with-uzt-ac-drainage-protection-system\/"},"modified":"2026-03-07T17:23:09","modified_gmt":"2026-03-07T17:23:09","slug":"kip-with-uzt-ac-drainage-protection-system","status":"publish","type":"product","link":"https:\/\/kmgr.kz\/en\/product\/kip-with-uzt-ac-drainage-protection-system\/","title":{"rendered":"KIP with UZT (AC Drainage Protection System)"},"content":{"rendered":"<p>The UZT device is \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u043e for diverting alternating current induced as a result of electromagnetic \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 from high-voltage overhead power lines and other high-voltage sources. The device does not affect the protective potential created by the cathodic protection (CP) system of the pipeline.<\/p>\n<p>UZT should be installed in locations with hazardous influence of AC sources from overhead and cable power lines with voltage of 110 kV and higher, as well as AC electrified railways, namely:<\/p>\n<ul>\n<li>along sections where the pipeline runs parallel to overhead lines (OHL), cable lines (CL), or electrified railways;<\/li>\n<li>at pipeline crossings with OHL, CL, or electrified railways;<\/li>\n<li>at points where pipelines approach or diverge from OHL, CL, or electrified railways.<\/li>\n<\/ul>\n<p><strong>Main functions of the AC drainage protection system:<\/strong><\/p>\n<ul>\n<li>diverting AC induced in the pipeline by high-voltage power lines through the grounding circuit;<\/li>\n<li>preventing leakage of the CP protective potential, unlike standard pipeline grounding;<\/li>\n<li>measuring the diverted AC current via a transformer integrated into the unit\u2019s circuit.<\/li>\n<\/ul>\n<p><strong>The UZT is a box housing the following components:<\/strong><\/p>\n<ul>\n<li>a capacitor unit for diverting AC to the grounding device;<\/li>\n<li>surge protection device against atmospheric overvoltages (lightning protection) \u2014 gas discharge arrester;<\/li>\n<li>a transformer for measuring the diverted AC current;<\/li>\n<li>a frequency filter (standard version with 1100 Hz cutoff) to prevent leakage of AC of a fixed frequency when electrochemical equipment is installed on the pipeline.<\/li>\n<\/ul>\n<p><strong>Scope of supply<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Name<\/strong><\/td>\n<td><strong>Unit<\/strong><\/td>\n<td><strong>Quantity<\/strong><\/td>\n<\/tr>\n<tr>\n<td>KIP.KMG post with UZT<\/td>\n<td>pcs<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Key for terminal panel cover<\/td>\n<td>pcs<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Grounding electrode with fastening hardware<\/td>\n<td>set<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Cable (type specified in the Customer\u2019s technical requirements)<\/td>\n<td>m<\/td>\n<td>as ordered<\/td>\n<\/tr>\n<tr>\n<td>Operation manual<\/td>\n<td>copy<\/td>\n<td>1 per batch<\/td>\n<\/tr>\n<tr>\n<td>Passport<\/td>\n<td>copy<\/td>\n<td>1 per batch<\/td>\n<\/tr>\n<tr>\n<td>Anchor device preventing free extraction of the KIP post from the ground<\/td>\n<td>pcs<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Kilometer marker (upon Customer\u2019s request)<\/td>\n<td>pcs<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Aerosol paint (1 can per 10 markers when ordering a kilometer marker)<\/td>\n<td>pcs<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Number stencil set<\/td>\n<td>set<\/td>\n<td>as ordered<\/td>\n<\/tr>\n<tr>\n<td>Spare parts kit (ZIP)<\/td>\n<td>set<\/td>\n<td>as ordered<\/td>\n<\/tr>\n<tr>\n<td>Agrotechnical cover<\/td>\n<td>m\u00b2<\/td>\n<td>as ordered<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Instrumentation and control posts can be equipped with additional anticorrosion protection system devices that expand their functionality, including an alternating current drainage protection system (UZT).<\/p>\n","protected":false},"featured_media":13075,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"product_brand":[],"product_cat":[139],"product_tag":[160,162],"class_list":["post-13074","product","type-product","status-publish","has-post-thumbnail","product_cat-test-and-measurement-points","product_tag-instrumentation-and-control-post-icp-for-oil-pipelines","product_tag-instrumentation-and-control-post-icp-with-additional-equipment","first","onbackorder","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/product\/13074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/media\/13075"}],"wp:attachment":[{"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/media?parent=13074"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/product_brand?post=13074"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/product_cat?post=13074"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/kmgr.kz\/en\/wp-json\/wp\/v2\/product_tag?post=13074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}