Description
The ICP P02 model is a measuring unit designed to perform measurements on underground pipelines. Purchasing an Instrumentation and Control Post (ICP) is required when it is necessary to monitor parameters and the level of protection against corrosion formation.
ICP can be ordered in two versions – P01 and P02. The second option is distinguished by the presence of an additional mechanism. Functional add-ons may also include an anticorrosion protection system, grounding, current monitoring, etc. These options expand the functionality of instrumentation and control posts.
ICP Type P02 is a polymer post with a square cross-section. The wall thickness is 4 mm and the side width is 20 cm. The material used to manufacture the device does not support combustion. The post is embedded in the ground to a depth of 50 cm or more. Its length can range from 180 to 300 cm and depends on the customer’s requirements. The final price of ICP Type P02 is formed based on this.
The model is equipped with a retractable mechanism made of a material resistant to corrosion. A technological opening is located at the bottom of the unit. During installation, the opening must be positioned below the burial level. The ICP design includes information plates, a signal cap, a terminal panel, lifting and sliding, and locking mechanisms.
Product Specifications
| Specifications | Parameters |
| Material type | polyvinyl chloride |
| Cross-section shape | square |
| Corners | reinforced |
| Moisture protection rating | IP34 |
| Weight, kg | 17 |
| Bending resistance, kN | 5 |
| Face width, cm | 20 |
| Length, cm | 200 |
The manufacturer has set maximum and minimum operating temperatures. The ICP can be used at temperatures from -60 to +60 degrees Celsius. Delivery of ICP Type P02 and optional equipment is specified at the order placement stage.