Instrumentation and Control Post (ICP) with UZZ (Device for Protection of Pipelines from Induced Alternating Current)

$0.00

UZZ is designed to divert alternating current возникающее as a result of electromagnetic influence from high-voltage power transmission lines and other high-voltage sources. At the same time, the device does not disturb the protective potential generated by the electrochemical protection system of the pipeline.

Description

You can buy an ICP with a protection device against induced alternating current in two modifications. Instrumentation and Control Posts with UZZ are designed to protect metal pipelines from current effects. Depending on the modification, they can eliminate the influence of power lines or provide lightning protection.

The measuring posts are made in the form of an elongated square or triangular post manufactured from durable, non-combustible material. The device housing features information markings and a panel for cable output and connection. You can order an ICP with UZZ with a cross-section of 20×1 cm in a square shape or with a cross-section of 18×1 cm in a triangular shape.

As grounding, the unit is equipped with steel strips. To achieve the required length, they are connected to each other with bolts and nuts. One section of the grounding strip is about 3 meters long and is determined individually in each case. The board with the electrical circuit is made of fiberglass laminate, and the operation of the device is regulated by a spark gap (varistor).

Product Specifications

Installation of the equipment is carried out in areas of possible exposure to sources of alternating current. The price of the product depends on the material used for the grounding device, as specified by the customer.

Specifications Parameters UZZ-G Parameters UZZ-L
Weight, kg depends on the order depends on the order
Number of terminals, pcs 8 8
Regulating element spark gap varistor
Impulse current, A max 24 max 20
Overvoltage limitation, V 250 75
Grounding size, mm rod or strip 4×40 strip 4×40

 

The device can be used at minimum temperatures down to -40 and maximum up to +40 degrees Celsius. Delivery of the ICP and additional configuration are discussed individually with the customer.

Contacts
Adress

Republic of Kazakhstan, Aktau, industrial zone 3, site 2, KM GROUP production base