Description
Instrumentation and Control Posts (ICP) must be purchased to perform work on protecting underground utilities from corrosion. ICPs are used for monitoring gas pipelines laid in temperate and moderately cold climates in accordance with GOST requirements.
ICP Type 6 is a post with three faces, each 18 cm wide. Its installation involves embedding the unit directly above the inspected facility. The ICP is made of a material resistant to fire and frost. The housing is marked with the information required for operation.
The ICP can be ordered with a signal cap and a kilometer marker sign. Unauthorized dismantling is prevented by a special device. For connection to cathodic protection (CP), a control panel with terminals and clamps is located at the top of the housing. It is equipped with a cover that can be locked. Measuring equipment is connected to boards with power terminals.
Cable routing is carried out through a technological opening located at the bottom of the unit. The burial depth of the ICP in the ground must be at least 70 cm. This parameter is indicated in a special window on the post. The price of the ICP Type 6 depends on the optional configuration selected by the customer.
Product Specifications
The product consists of a post covered with a signal cap with reflective elements. An agrotechnical coating can be added to the scope of supply at the customer’s request.
| Parameter name | ICP Type-6 | ||
| Post height, mm | 1500-2100 | ||
| Face width, mm | 180 | ||
| Wall thickness, mm | 3 | ||
| Weight, kg, max | 15 | ||
| Bending resistance at a distance of 0.7 m from the ground surface | not less than 0.8 kN | ||
| Enclosure protection rating | not less than IP23 | ||
| Operating temperature range, °C | U1, -40 °C … +60 °C; UHL1, -60 °C … +60 °C | ||
| Number of contact clamps on the terminal panel: | |||
| – measuring clamps for cables up to 6 mm², pcs. | 0, 4, 6, 8, 12, 24 | ||
| – power clamps for cables up to 35 mm², pcs. | 0, 4, 6, 8 | ||
| Service life, years | not less than 10 years | ||
Scope of Supply
| Name | Unit | Quantity |
| ICP post | pcs. | 1 |
| Key for the terminal panel cover | pcs. | 1 |
| Marker | pcs. | 1 |
| Marking tags | pcs. | according to the number of clamps |
| Cable tie | pcs. | |
| Operation manual | copy | 1 per batch |
| Device preventing free extraction of the ICP post from the ground | pcs. | 1 |
| * Optional devices | ||
| * Kilometer marker sign | pcs. | 1 |
| * Aerosol paint (1 can per 10 signs when ordering a kilometer sign) | pcs. | 1 |
| * Number stencil (when ordering a kilometer sign) | Set | as ordered |
| * Power cables and measuring wires: – measuring – up to 6 mm²; – power – up to 25 mm²; – drainage to grounding device – up to 35 mm². |
m | as ordered |
| * Spare parts kit | Set | as ordered |
| * Agrotechnical coating | m² | as ordered |
*Supplied upon additional order
Details:
| Post height, mm | 2000-2700 |
|---|---|
| Face width, mm | 180 |
| Post cross-section | equilateral triangle |
| Weight, kg, max | 20 |
| Degree of protection against external impacts | IP34 |
| Post bending resistance, kN, min | 5 |
| Post material | frost-resistant unplasticized polyvinyl chloride non-combustible solid-drawn seamless self-supporting with reinforced (strengthened) corners |