Instrumentation and control post (ICP), type 2

Composition of the product:

  • Four-sided information post made of frost- and fire-resistant polymer composite with applied informational inscriptions;
  • Signal cap with reflective elements;
  • Terminal panel cover with a lock, allowing installation of external measuring equipment and field operations;
  • Terminal panel with contact clamps for connecting cables and equipment;
  • Technological opening for cable line (CL) entry;
  • Anchoring device for reliable fixation of the post in the ground;
  • Agrotechnical coating supplied upon customer request.

 

Description

KM GROUP offers certified instrumentation and control posts (ICP) TYPE 2. They are intended for monitoring the condition and regulating the operation of cathodic protection (CP) systems installed on underground structures. They are also used to mark the route of pipelines.

The ICP TYPE 2 design is made in the form of a four-sided post with equal faces. The width of each face is 200 mm. Markings and warning inscriptions made with abrasion-resistant paint are applied to the faces. The post is installed directly into the ground above pipelines and other underground structures. The material used for ICP TYPE 2 is a high-strength polymer that is non-combustible and resistant to temperature fluctuations, wind, and precipitation.

A signal cap is installed at the top of the post. Optionally, the product can be supplied with a kilometer marker.

A terminal panel for connecting measuring devices is located at the top. It is protected by a cover with a lock.

A technological opening is provided at the bottom of the post for cable entry.

The post is equipped with an anti-vandal protection system. An anchoring device is fixed in the lower part of ICP TYPE 2, preventing the post from being freely pulled out of the ground.

For long-term and safe operation, it is recommended to embed the post into the ground to a depth of 0.7 m or more. The minimum installation level is marked on the product body.

ICP TYPE 2 units are supplied on request in any quantities. Please contact our representative for pricing information.

Technical specifications

Name Specification
Overall height from 1500 to 2700 mm (according to customer requirements)
Face width 200 mm
Polymer material thickness 3 mm
Weight up to 15 kg
Bending resistance at 0.7 m above ground level not less than 0.8 kN
Ingress protection rating not less than IP23
Permissible operating temperature range U1, –40 °C … +60 °C; UHL1, –60 °C … +60 °C
Number of terminal clamps on the terminal panel:
– measuring terminals for cables up to 6 mm² 0, 4, 6, 8, 12, 24 pcs.
– power terminals for cables up to 35 mm² 0, 4, 6, 8 pcs.
Minimum service life 10 years

 

Contacts
Adress