Instrumentation and control post (ICP), type 1

$0.00

ICP Type 1 is designed for switching power and measuring circuits of cathodic protection (CP) system equipment.

Description

We offer to purchase instrumentation and control posts (ICP) — key elements of cathodic protection systems (CP) that ensure reliable operation and monitoring of underground metal structures.

Purpose and functions of ICP

ICP units are intended for switching power and measuring circuits, controlling parameters, and ensuring stable functioning of CP systems. Main tasks:

  • Switching power circuits — supplying and distributing cathodic protection current.
  • System parameter control — measuring currents, voltages, and potentials.
  • Pipeline condition monitoring — connecting measuring instruments for operational diagnostics.
  • Operational safety — preventing accidents and ensuring stable corrosion protection.

Installation and standards

Installation of ICP units is carried out in accordance with the requirements of:
GOST R 51164, RD-33.040.99-KTN-210-10, RD-91.020.00-KTN-234-10, etc.

Instrumentation and control posts are installed:

  • At every kilometer of the pipeline route.
  • In zones affected by stray currents and aggressive soils.
  • At a distance of three pipe diameters from CP installations.
  • Near valve sites and at the boundaries of protection zones.
  • One on each bank of underwater crossings; if the water protection zone width exceeds 500 m — two on both sides.
  • At intersections with other utilities, roads, and engineering structures.

Design and configuration

  • Triangular post made of frost- and fire-resistant composite material (180 mm side).
  • Signal cap with reflective elements.
  • Terminal panel with contact clamps.
  • Terminal compartment cover with lock.
  • Cable entry opening.
  • Anti-vandal anchoring device.
  • Optional indicator boards or kilometer markers.

Main mass and dimensional parameters:

Parameter name Type 1
Post height, mm 2500
Face width, mm 180 ± 1
Depth of installation in soil (marked on the post), mm 700
Weight (without additional equipment), kg 13±0.5

Advantages of ICP

  • Easy installation and low weight.
  • High strength — bending resistance up to 2.5 kN.
  • Possibility to place CP blocks and sensors inside the housing.
  • Material does not shield signals and is fire resistant.
  • Operating temperature range from –60 °C to +60 °C.
  • No seasonal maintenance required.
  • Possibility of custom design to match customer corporate style.

Additional options

ICP units can be additionally equipped with:

  • Joint protection blocks (JPB).
  • Devices for monitoring the current of anode ground beds and sacrificial anodes.
  • Lightning protection equipment.
  • Systems for draining alternating currents.

Example of designation

ICP 1.12-4.T.K, where:

1 — post type (triangular section 180 mm),
12-4 — number of measuring and power terminals,
T — presence of an indicator board,
K — presence of a kilometer marker.

Details:

Post height, mm 2000-2500
Face width, mm 180
Post cross-section triangle
Corner reinforcement yes
Weight, kg 9,5
Ingress protection rating IP34
Bending resistance of post, kN, min 5
Permissible ambient temperatures, °C -60…+60
Post material морозостойкий непластифицированный поливинилхлорид
негорючий
цельнотянутый
бесшовный
самонесущий
с армированными (усиленными) углами

 

Contacts
Adress

Republic of Kazakhstan, Aktau, industrial zone 3, site 2, KM GROUP production base